Values of effective pulmonary blood flow (QEP) and cardiac output, determined by a non-invasive foreign gas rebreathing method (CORB) using a new infrared photoacoustic gas analysing system, were compared with measurements of cardiac output obtained by the direct Fick (COFICK) and thermodilution (COTD) methods in patients with heart failure or pulmonary hypertension. In 11 patients, of which three had shunt flow through areas without significant gas exchange, the mean difference (bias) and limits of agreement (±2S.D.) were 0.6±1.2litreċmin-1 when comparing COFICK and QEP, and -0.8±1.3litreċmin-1 when comparing COFICK and COTD. When correction for intrapulmonary shunt flow was applied (i.e. calculation of CORB) in all 11 patients, the bias between COFICK and CORB was 0.1±0.9litreċmin-1, primarily because agreement improved in the three patients with significant shunt flow. In the eight patients without significant shunt flow, the agreement between QEP and COFICK was 0.3±0.9litreċmin-1. In conclusion, a foreign gas rebreathing method with a new infrared photoacoustic gas analyser provided at least as reliable a measure of cardiac output as did thermodilution. In the absence of significant shunt flow, measurement of QEP itself provides a reliable estimate of cardiac output in heart failure patients. The infrared photoacoustic gas analyser markedly facilitates clinical use of the rebreathing method in general, which makes the method available to a larger group of clinicians working with patients with cardiovascular diseases.
Skip Nav Destination
Article navigation
Research Article|
January 14 2002
Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
Anders GABRIELSEN;
*Clinic of Aviation Medicine, The Heart Centre, National University Hospital (Rigshospitalet) Dept. 7805, DK-2200 Copenhagen, Denmark
Correspondence: Dr Anders Gabrielsen (e-mail [email protected]).
Search for other works by this author on:
Regitze VIDEBÆK;
Regitze VIDEBÆK
†Department of Cardiology, The Heart Centre, National University Hospital (Rigshospitalet), DK-2100 Copenhagen, Denmark
Search for other works by this author on:
Morten SCHOU;
Morten SCHOU
*Clinic of Aviation Medicine, The Heart Centre, National University Hospital (Rigshospitalet) Dept. 7805, DK-2200 Copenhagen, Denmark
Search for other works by this author on:
Morten DAMGAARD;
Morten DAMGAARD
*Clinic of Aviation Medicine, The Heart Centre, National University Hospital (Rigshospitalet) Dept. 7805, DK-2200 Copenhagen, Denmark
Search for other works by this author on:
Jens KASTRUP;
Jens KASTRUP
†Department of Cardiology, The Heart Centre, National University Hospital (Rigshospitalet), DK-2100 Copenhagen, Denmark
Search for other works by this author on:
Peter NORSK
Peter NORSK
*Clinic of Aviation Medicine, The Heart Centre, National University Hospital (Rigshospitalet) Dept. 7805, DK-2200 Copenhagen, Denmark
Search for other works by this author on:
Publisher: Portland Press Ltd
Received:
May 08 2001
Revision Received:
August 28 2001
Accepted:
October 19 2001
Online ISSN: 1470-8736
Print ISSN: 0143-5221
The Biochemical Society and the Medical Research Society © 2002
2002
Clin Sci (Lond) (2002) 102 (2): 247–252.
Article history
Received:
May 08 2001
Revision Received:
August 28 2001
Accepted:
October 19 2001
Citation
Anders GABRIELSEN, Regitze VIDEBÆK, Morten SCHOU, Morten DAMGAARD, Jens KASTRUP, Peter NORSK; Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci (Lond) 1 February 2002; 102 (2): 247–252. doi: https://doi.org/10.1042/cs1020247
Download citation file:
Sign in
Don't already have an account? Register
Sign in to your personal account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.