The incidence of ventricular tachyarrhythmias in the early post-operative period following implantable cardioverter-defibrillator (ICD) implantation is relatively high compared with that in control periods. Since endothelin-1 (ET-1) has been proven to be an endogenous arrhythmogenic substance, we investigated the changes in serum ET-1 and big-ET levels in patients undergoing ICD implantation. Serum concentrations of ET-1 and big-ET were measured in 14 patients with various heart diseases before the operation, as well as 1min and 1h after the last shock therapy. Big-ET levels and the sum of ET-1 and big-ET levels were unchanged immediately after the operation, but had increased significantly by 1h after implantation (before, 1.57±0.61pmol/l; 1min, 1.86±0.87pmol/l; 1h, 4.29±1.65pmol/l for big-ET; before, 3.44±1.07pmol/l; 1min, 3.79±1.29pmol/l; 1h, 6.36±2.03pmol/l for big-ET+ET-1). There was a significant correlation between left ventricular ejection fraction and big-ET level measured 1h after the last shock delivery (r =-0.542, P<0.05). We conclude that the increased big-ET level observed 1h after the last induction and shock therapy of ventricular fibrillation might have a pathophysiological role in the increased incidence of post-operative spontaneous ventricular arrhythmias.
Skip Nav Destination
Article navigation
September 2002
-
Cover Image
Cover Image
Conference Article|
September 01 2002
Effects of implantable cardioverter defibrillator implantation and shock application on serum endothelin-1 and big-endothelin levels
Andrea SZÜCS;
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Dr Andreas Szücs (e-mail [email protected]).
Search for other works by this author on:
Katalin KELTAI;
Katalin KELTAI
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Endre ZIMA;
Endre ZIMA
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Hajnalka VÁGÓ;
Hajnalka VÁGÓ
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Pál SOÓS;
Pál SOÓS
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Attila RÓKA;
Attila RÓKA
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Zoltán SZABOLCS;
Zoltán SZABOLCS
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
László GELLÉR;
László GELLÉR
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Béla MERKELY
Béla MERKELY
1Department of Cardiovascular Surgery, Semmelweis University, Városmajor u. 68. H-1122 Budapest, Hungary
Search for other works by this author on:
Publisher: Portland Press Ltd
Online ISSN: 1470-8736
Print ISSN: 0143-5221
© 2002 The Biochemical Society and the Medical Research Society
2002
Clin Sci (Lond) (2002) 103 (s2002): 233S–236S.
Citation
Andrea SZÜCS, Katalin KELTAI, Endre ZIMA, Hajnalka VÁGÓ, Pál SOÓS, Attila RÓKA, Zoltán SZABOLCS, László GELLÉR, Béla MERKELY; Effects of implantable cardioverter defibrillator implantation and shock application on serum endothelin-1 and big-endothelin levels. Clin Sci (Lond) 1 September 2002; 103 (s2002): 233S–236S. doi: https://doi.org/10.1042/CS103S233S
Download citation file:
Sign in
Don't already have an account? Register
Sign in to your personal account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.