Portapres® derives continuous estimates of cardiac output from the peripheral pulse and has the potential to be an extremely valuable physiological and clinical tool. We assessed Portapres® estimates of cardiac output in healthy subjects at rest, during maximal treadmill exercise (n=8) and during decreases caused by orthostatic stress (n=8). Comparison with a rebreathing method indicated that Portapres® tended to overestimate cardiac output. The random errors of the estimates (precision), expressed as ±2 S.D. of the differences between paired estimates during steady states, ranged between 1.2 and 2.6 litres/min. We conclude that these errors indicate that the method is probably only useful for assessing changes in individual subjects where large changes are anticipated, as during exercise. When smaller changes occur, as during orthostasis, the errors preclude the use of individual subject data and only permit group average data to be examined.
Skip Nav Destination
Article navigation
April 2004
-
Cover Image
Cover Image
- PDF Icon PDF LinkTable of Contents
Research Article|
April 01 2004
Cardiac output by Portapres®
Marjorie S. PITT;
Marjorie S. PITT
1Institute for Cardiovascular Research, University of Leeds, Leeds LS2 9JT, U.K.
Search for other works by this author on:
Paul MARSHALL;
Paul MARSHALL
1Institute for Cardiovascular Research, University of Leeds, Leeds LS2 9JT, U.K.
Search for other works by this author on:
Jonathan P. DIESCH;
Jonathan P. DIESCH
1Institute for Cardiovascular Research, University of Leeds, Leeds LS2 9JT, U.K.
Search for other works by this author on:
Roger HAINSWORTH
1Institute for Cardiovascular Research, University of Leeds, Leeds LS2 9JT, U.K.
Correspondence: Professor R. Hainsworth (e-mail [email protected]).
Search for other works by this author on:
Publisher: Portland Press Ltd
Received:
August 19 2003
Revision Received:
November 18 2003
Accepted:
December 12 2003
Accepted Manuscript online:
December 12 2003
Online ISSN: 1470-8736
Print ISSN: 0143-5221
© 2004 The Biochemical Society
2004
Clin Sci (Lond) (2004) 106 (4): 407–412.
Article history
Received:
August 19 2003
Revision Received:
November 18 2003
Accepted:
December 12 2003
Accepted Manuscript online:
December 12 2003
Citation
Marjorie S. PITT, Paul MARSHALL, Jonathan P. DIESCH, Roger HAINSWORTH; Cardiac output by Portapres®. Clin Sci (Lond) 1 April 2004; 106 (4): 407–412. doi: https://doi.org/10.1042/CS20030279
Download citation file:
Sign in
Don't already have an account? Register
Sign in to your personal account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.