The present study compares the spectral characteristics of 24-h blood pressure variability estimated invasively at the brachial artery level with those estimated by measurement of blood pressure at the finger artery using the non-invasive Portapres device. Broad-band spectra (from 3×10-5 to 0.5 Hz) were derived from both finger and intra-brachial pressures recorded simultaneously for 24 h in eight normotensive and twelve hypertensive ambulant subjects. At frequencies lower than 0.07 Hz, higher spectral estimates were obtained by Portapres than by intra-brachial measurements. The maximum overestimation occurred in systolic pressure at around 10-2 Hz, where the amplitude of the oscillations was two times greater when measured by Portapres. A less pronounced overestimation was found for diastolic pressures. The maximum overestimation was greater during daytime than during night-time. At around 0.1 Hz, invasive and non-invasive spectra were similar. At the respiratory frequencies (0.15-0.50 Hz), the power spectra were overestimated by Portapres during daytime, and underestimated at night. These results provide reference information for the correct interpretation of Portapres data in the estimation of 24-h blood pressure spectral power.
Skip Nav Destination
Article navigation
Research Article|
June 16 1999
Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings
Paolo CASTIGLIONI;
*LaRC, Centro di Bioingegneria, Fondazione Don C. Gnocchi and Politecnico di Milano, via Gozzadini 7, I-20148 Milan, Italy
Correspondence: Dr Paolo Castiglioni.
Search for other works by this author on:
Gianfranco PARATI;
Gianfranco PARATI
†Istituto Scientifico Ospedale S. Luca, Istituto AuxologicoItaliano, Milan, Italy
Search for other works by this author on:
Stefano OMBONI;
Stefano OMBONI
†Istituto Scientifico Ospedale S. Luca, Istituto AuxologicoItaliano, Milan, Italy
Search for other works by this author on:
Giuseppe MANCIA;
Giuseppe MANCIA
‡Clinica Medica, Universita di Milano, Ospedale S. Gerardo, Monza, Italy
Search for other works by this author on:
Ben P. M. IMHOLZ;
Ben P. M. IMHOLZ
§TNO BiomedicalInstrumentation, Academic Medical Centre, Amsterdam, The Netherlands
Search for other works by this author on:
Karel H. WESSELING;
Karel H. WESSELING
§TNO BiomedicalInstrumentation, Academic Medical Centre, Amsterdam, The Netherlands
Search for other works by this author on:
Marco DI RIENZO
Marco DI RIENZO
*LaRC, Centro di Bioingegneria, Fondazione Don C. Gnocchi and Politecnico di Milano, via Gozzadini 7, I-20148 Milan, Italy
Search for other works by this author on:
Publisher: Portland Press Ltd
Received:
December 02 1998
Revision Received:
March 12 1999
Accepted:
April 16 1999
Online ISSN: 1470-8736
Print ISSN: 0143-5221
The Biochemical Society and the Medical Research Society © 1999
1999
Clin Sci (Lond) (1999) 97 (2): 129–139.
Article history
Received:
December 02 1998
Revision Received:
March 12 1999
Accepted:
April 16 1999
Citation
Paolo CASTIGLIONI, Gianfranco PARATI, Stefano OMBONI, Giuseppe MANCIA, Ben P. M. IMHOLZ, Karel H. WESSELING, Marco DI RIENZO; Broad-band spectral analysis of 24 h continuous finger blood pressure: comparison with intra-arterial recordings. Clin Sci (Lond) 1 August 1999; 97 (2): 129–139. doi: https://doi.org/10.1042/cs0970129
Download citation file:
Sign in
Don't already have an account? Register
Sign in to your personal account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
Biochemical Society Member Sign in
Sign InSign in via your Institution
Sign in via your InstitutionGet Access To This Article
Cited By
Open Access for all
We offer compliant routes for all authors from 2025. With library support, there will be no author nor reader charges in 5 journals. Check here |
![]() |